Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
18741 TYCO ELECTRONICS CORPORATION DBA KIL

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
AKDX WINDING QUANTITY 1
AAJD THREAD CLASS 2A SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION SALT SPRAY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
ABHP OVERALL LENGTH 3.312 INCHES MAXIMUM
APCN COIL QUANTITY 1
AAJF THREAD DIRECTION RIGHT-HAND SINGLE MOUNTING FACILITY
APNA WINDING DC RESISTANCE RATING 4.5 OHMS MINIMUM SINGLE WINDING AND 5.5 OHMS MAXIMUM SINGLE WINDING
ADAV OVERALL DIAMETER 1.750 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 6.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
THSD THREAD SERIES DESIGNATOR UN SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 3.0 AMPERES DC RESISTIVE LOAD
CQJX NOMINAL THREAD SIZE 1.125 INCHES SINGLE MOUNTING FACILITY
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING SINGLE MOUNTING FACILITY
CRXH TIME DELAY 0.015 SECONDS NOMINAL FIXED OPERATE TIME
CMLP THREAD QUANTITY PER INCH 32 SINGLE MOUNTING FACILITY

Similar Parts

H-16/S4 , H16S4 , 5945-00-458-8749 , 5945004588749 , 004588749