Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
09349 | MAGNETIC CIRCUIT ELEMENTS INC DBA M |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABHP | OVERALL LENGTH | 3.360 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 3.060 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 0.166 INCHES MINIMUM SINGLE GROUP AND 0.218 INCHES MAXIMUM SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAT | BODY WIDTH | 1.560 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
AKNA | INCLOSURE TYPE | OPEN |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
AGAV | END ITEM IDENTIFICATION | PSTRATEGIC SEALIFT CONVERSION SHIPS CLASS, WATERS CLASS TAGS-45, VICTORIOUS CLASS T-AGOS 19, HAYES CLASS T-AG 195, BOB HOPE CLASS T-AKR 300, T-AKR 310 CLASS, WHIDBEY ISLAND CLASS LSD, USNS HENERY J. KAISER CLASS TAO. |