National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
| Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
|---|---|---|---|---|---|---|---|---|
| 2060-437-9 | 11871 | A | 3 | 2 | A | TX | ||
| FW1102S12 | 58614 | A | 5 | 9 | 5 | ZZ | ||
| FW1102S12 | 00779 | A | 5 | 2 | 5 | ZZ | ||
| 2B-5067 | 02289 | H | 5 | 9 | 6 | 9Z | ||
| BR8-600B24A17 | 56623 | A | 5 | 1 | E | TX | ||
| P26B46J6A1 | 99699 | A | 5 | 2 | 5 | TX |
CAGE Information
| Code | Company |
|---|---|
| 00779 | TYCO ELECTRONICS CORPORATION |
| 11871 | RECON/OPTICAL INC. |
| 58614 | TYCO ELECTRONICS CORPORATION DBA CII |
| 02289 | HI-G CO INC SUB OF NYTRONICS INC |
| 56623 | MICROSEMI CORP.-POWER MANAGEMENT GRO |
| 99699 | DRI RELAYS INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
| MRC | Requirements Statement | Clear Text Reply |
|---|---|---|
| AFRG | CONTACT MATERIAL | SILVER |
| AFRG | CONTACT MATERIAL | SILVER |
| AKDX | WINDING QUANTITY | 1 |
| CRXH | TIME DELAY | 0.005 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| PRMT | PRECIOUS MATERIAL | SILVER AND GOLD |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
| ABHP | OVERALL LENGTH | 1.360 INCHES MAXIMUM |
| APCN | COIL QUANTITY | 1 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| APNQ | ARC QUENCHING METHOD | AIR |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| CBME | CUBIC MEASURE | 0.543 CUBIC INCHES |
| APNA | WINDING DC RESISTANCE RATING | 600.0 OHMS NOMINAL SINGLE WINDING |
| PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER AND CONTACT SURFACES GOLD |
| APNP | DUTY TYPE | CONTINUOUS |
| ABKW | OVERALL HEIGHT | 0.392 INCHES MAXIMUM |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| ADTV | CASE MATERIAL | METAL |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| AFRH | CONTACT SURFACE TREATMENT | GOLD |
| ABMK | OVERALL WIDTH | 1.020 INCHES MAXIMUM |
Similar Parts
FW1102S12 ,
FW1102S12 ,
5945-00-087-5874 ,
5945000875874 ,
000875874
,
2060-437-9 ,
FW1102S12 ,
FW1102S12 ,
2B-5067 ,
BR8-600B24A17 ,
P26B46J6A1 ,