NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
A-114938 | 71482 | R | 5 | 9 | 1 | TX | ||
0490-0047 | 1LQK8 | A | 3 | 2 | 5 | ZZ | ||
A-114938 | 00779 | A | 5 | 2 | 1 | TX | ||
LS-2511-2 | 77342 | A | 5 | 9 | 1 | TX | ||
A-114938 | D0080 | A | 5 | 2 | 5 | ZG | ||
0490-0047 | 28480 | A | 5 | 9 | 1 | ZG | ||
A-114938 | 58614 | A | 5 | 9 | 1 | TX | ||
A114938 | 1E9M5 | A | C | 1 | 6 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
00779 | TYCO ELECTRONICS CORPORATION |
71482 | CP CLARE CORP NORTH AMERICAN SALES O |
1LQK8 | AGILENT TECHNOLOGIES INC. DIV AGILEN |
77342 | TYCO ELECTRONICS CORPORATION |
D0080 | LEACH INTERNATIONAL GERMANY GMBH |
28480 | HEWLETT PACKARD CO |
58614 | TYCO ELECTRONICS CORPORATION DBA CII |
1E9M5 | C P CLARE CORP |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
CBME | CUBIC MEASURE | 3.993 CUBIC INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
APNA | WINDING DC RESISTANCE RATING | 10.0 OHMS NOMINAL SINGLE WINDING |
ABHP | OVERALL LENGTH | 1.438 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ABMK | OVERALL WIDTH | 1.125 INCHES MAXIMUM |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNP | DUTY TYPE | CONTINUOUS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
ADTV | CASE MATERIAL | METAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 30.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE ALL FUNCTIONS |
ABKW | OVERALL HEIGHT | 2.468 INCHES MAXIMUM |