NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
627CSERIES | 58657 | A | 5 | 9 | 5 | TX | ||
1006752 | 10001 | A | 3 | 2 | X | XX | ||
R-11155 | 31143 | F | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
58657 | LEACH INTERNATIONAL CORPORATION DBA |
31143 | ZENITRON MFG CORP DBA NORTHEAST MFG |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 235.0 OHMS NOMINAL SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
CBBL | FEATURES PROVIDED | POLARIZED |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES DC SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 11 PIN ALL FUNCTIONS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 3C |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC |
APNP | DUTY TYPE | CONTINUOUS |
ABHP | OVERALL LENGTH | 3.180 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 1.780 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC RESISTIVE LOAD |