NIIN Output Data
NIIN:
NSN:
Item Name:
THERMOSTAT , FLOW CONTROL
Definition:
AN AUTOMATIC REGULATING DEVICE WHICH CONTROLS THE FLOW OF FLUIDS OR GASES BY ACTUATING A VALVE OR SHUTTER FOR HEATING OR COOLING PURPOSES. MAY BE ADJUSTABLE, OR SET TO OPERATE AT A DEFINITE PRESSURE. EXCLUDES CONTROL, HUMIDITY; CONTROL, TEMPERATURE INDICATING; AND SWITCH, THERMOSTATIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
269138 | 71995 | A | 5 | 9 | 4 | SB | ||
I-1701-A | 73475 | A | 3 | 2 | 5 | SB |
CAGE Information
Code | Company |
---|---|
71995 | DRESSER INDUSTRIES INC WAUKESHA ENGI |
73475 | ROBERTSHAW CONTROLS COMPANY |
Federal Supply Class
Title
PRESSURE, TEMPERATURE, AND HUMID
Inclusions:
INCLUDES THERMOMETERS, INCLUDING ENGINE THERMOMETERS; PRESSURE GAGES; THERMOCOUPLE LEADS; RESISTANCE BULBS.
Exclusions:
EXCLUDES CLINICAL THEROMETERS; (FSC 6515); THERMOSTATIC AND DIFFERENTIAL PRESSURE SWITCHES (FSC 5930); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADQU | FLOW CONTROL DEVICE | CHOKE |
AMSD | VALVE TRAVEL DISTANCE | 0.260 INCHES NOMINAL |
ADJH | MOUNTING METHOD | FLANGE |
AGWM | LARGEST OUTSIDE DIAMETER | 2.490 INCHES NOMINAL |
ALCD | USAGE DESIGN | CONTROL ENGINE COOLANT TEMP |
AWTM | OPENING TEMP RATING | 160.0 DEG FAHRENHEIT NOMINAL |
ABKW | OVERALL HEIGHT | 1.563 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | 182.0 DEG FAHRENHEIT NOMINAL |
AWTP | SPRING OPERATED PRESSURE RELIEF | NOT PROVIDED |
AWPA | THERMOSTAT TYPE | BELLOWS-BIMETALLIC |