NIIN Output Data
NIIN:
NSN:
Item Name:
COUPLER , DIRECTIONAL
Definition:
AN ITEM SPECIFICALLY DESIGNED TO BE INSERTED INTO A TRANSMISSION LINE, WAVEGUIDE OR COAXIAL TRANSMISSION LINE TO PROVIDE A SUITABLE TEST OUTLET. THE TEST SIGNAL IS ATTENUATED TO A PREDETERMINED VALUE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
950948-3 | 99899 | A | 5 | 2 | 5 | TX | ||
M-2543 | 12598 | A | 5 | 2 | 5 | ZZ | ||
950948-3 | 12457 | A | 5 | 2 | 5 | TX | ||
C2MT-30-4.7G/30805B | 12457 | A | 5 | 2 | 5 | TX | ||
950948-3 | 3B150 | A | 3 | 2 | A | ZZ |
CAGE Information
Code | Company |
---|---|
12457 | MERRIMAC INDUSTRIES INC |
99899 | L-3 COMMUNICATIONS CORPORATION DBA N |
12598 | R L C ELECTRONICS INC. |
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABHP | OVERALL LENGTH | 1.340 INCHES MINIMUM AND 1.410 INCHES MAXIMUM |
APGF | DESIGN TYPE | BIDIRECTIONAL OR UNIDIRECTIONAL |
BGPX | POWER LOSS IN DECIBELS | 50.0 |
BGPS | VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY | 1.25 TO 1 AT 5 GHZ |
ABKW | OVERALL HEIGHT | 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM |
APQB | UNIT TYPE | COAXIAL LINE |
ABMK | OVERALL WIDTH | 0.365 INCHES MINIMUM AND 0.395 INCHES MAXIMUM |
BGQC | TERMINAL FITTING USAGE DESIGN | MAIN LINE AND SECONDARY LINE |
ANKZ | RADIO FREQUENCY RATING | 4.4 GIGAHERTZ MINIMUM AND 5.0 GIGAHERTZ MAXIMUM |
BGPY | TERMINAL FITTING NAME | SMA PLUG COUPLING; SMA FEMALE COUPLING |