NIIN Output Data
NIIN:
NSN:
Item Name:
COOLER , FLUID , INDUSTRIAL
Definition:
AN APPARATUS DESIGNED TO LOWER THE TEMPERATURE OF A FLUID BY BRINGING IT INTO PROXIMITY WITH ANOTHER FLUID OF LOWER TEMPERATURE SO THAT HEAT TRANSFER IS EFFECTED BY CONDUCTION THROUGH THE WALLS OF SEPARATING CHAMBERS. EXCLUDES AIR CONDITIONING EQUIPMENT, REFRIGERATION EQUIPMENT, AND RADIATORS.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
5-144-02-024-003VM | 03950 | A | 5 | 2 | 6 | HD | ||
5-144-02-024-003 | 51900 | A | 3 | 1 | 3 | HD |
CAGE Information
Code | Company |
---|---|
03950 | NAVAL INVENTORY CONTROL POINT MECHAN |
51900 | ITT CORPORATION DBA ITT STANDARD |
Federal Supply Class
Title
HEAT EXCHANGERS AND STEAM CONDEN
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FEAT | SPECIAL FEATURES | SIZE OF TUBES-.250OD X 22 BWG X 24IN;SHELL SIDE-200PSI AT 300DEG F;TUBE SIDE-150PSI AT 300DEG F |
AWMZ | TUBE ATTACHMENT METHOD | ANY ACCEPTABLE |
CTRC | EFFECTIVE HEAT TRANSFER SURFACE AREA | 3.66 SQUARE FEET |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | MAGNETIC PERMEABILITY SHALL NOT EXCEED 2.0 AFTER FABRICATION |
BRXN | HEAT TRANSFER METHOD | INDIRECT |
ARNF | TUBE QUANTITY | 28 |