NIIN Output Data
NIIN:
NSN:
Item Name:
HEATER , WATER , ELECTRIC
Definition:
A UNIT SPECIFICALLY DESIGNED FOR HEATING WATER BY A DIRECT FIRED METHOD, UTILIZING ELECTRIC HEATING ELEMENT(S).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
S-12 480/3 | 20087 | A | 3 | 2 | E | AX |
CAGE Information
Code | Company |
---|---|
20087 | HATCO CORP |
Federal Supply Class
Title
SPACE AND WATER HEATING EQUIPMEN
Inclusions:
INCLUDES BOILERS, 15 POUNDS WSP AND UNDER (FOR BOILERS OVER 15 POUNDS WSP, SEE FSC 4410); DOMESTIC WATER STORAGE TANKS THROUGH 100 GALLON CAPACITY; FIREPLACE HEATERS; FURNACES; SPACE HEATERS; HEATING RADIATORS; IMMERSION HEATERS; WATER HEATERS, THROUGH 100 GALLON RECOVERY CAPACITY (FOR HEATERS OVER 100 GALLONS RECOVERY CAPACITY, SEE FSC 4410).
Exclusions:
EXCLUDES VEHICLE HEATERS; (FSC 2540); AIRCRAFT HEATERS (FSC 1660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
AMLR | WATER OUTLET CONNECTION QUANTITY | 1 |
AMHX | TEMP RISE PER HOUR | 40.0 DEG FAHRENHEIT |
ALHG | ATTACHMENT DEVICE | INCLUDED |
MATL | MATERIAL | STEEL, CORROSION RESISTING |
ELEC | VOLTAGE IN VOLTS | 480.0 |
AHGR | INSULATED FEATURE | NOT INCLUDED |
ABHP | OVERALL LENGTH | 23.500 INCHES NOMINAL |
FAAZ | PHASE | THREE |
AMJX | THERMOSTATIC SWITCH | INCLUDED |
AMLL | WATER INLET CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 3/4-14 NPT |
ABKW | OVERALL HEIGHT | 31.375 INCHES NOMINAL |
AMKA | TANK CAPACITY | 16.0 GALLONS |
AMHR | HEATING CAPACITY PER HOUR | 120.0 GALLONS |
AMLQ | WATER INLET CONNECTION QUANTITY | 1 |
AMRK | HEATING ELEMENT WATTAGE RATING | 1200.000 SINGLE |
ACDC | CURRENT TYPE | AC |
AMLM | WATER OUTLET CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 3/4-14 NPT |
ABAL | HEATING ELEMENT TYPE | SINGLE |
ABFY | OVERALL DEPTH | 22.750 INCHES NOMINAL |
AAJJ | MAXIMUM OPERATING PRESSURE | NOT RATED |