INVERTER , POWER , STATIC

Definition:

AN ITEM THAT CHANGES A DIRECT CURRENT INPUT INTO A SINGLE OR MULTIPLE PHASE ALTERNATING CURRENT OUTPUT, BY THE COMBINED ACTION OF OSCILLATORS, SEMICONDUCTOR DEVICES, MAGNETIC AMPLIFIERS, PHASE SPLITTERS, AND THE LIKE. FOR ITEMS THAT PERFORM THE SAME FUNCTION BY MEANS OF ROTATING MACHINE TECHNIQUES, SEE MOTOR-GENERATOR. SEE ALSO CONVERTER, FREQUENCY, STATIC.

CAGE Information

Code Company
10933 AVIONIC INSTRUMENTS INC

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ABKW OVERALL HEIGHT 2.750 INCHES NOMINAL
APTS OUTPUT FREQUENCY RATING 380.0 HERTZ MINIMUM SINGLE POWER OUTPUT AND 420.0 HERTZ MAXIMUM SINGLE POWER OUTPUT
AKAE MAXIMUM OPERATING ALTITUDE RATING 55000.0 FEET
APNX INPUT VOLTAGE RATING 24.0 DC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 34.0 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT
AKWC ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
ABHP OVERALL LENGTH 7.000 INCHES NOMINAL
APPA OUTPUT VOLTAGE RATING 25.0 AC VOLTS MINIMUM 1ST POWER OUTPUT AND 27.0 AC VOLTS MAXIMUM 1ST POWER OUTPUT
APPA OUTPUT VOLTAGE RATING 112.7 AC VOLTS MINIMUM 2ND POWER OUTPUT AND 117.3 AC VOLTS MAXIMUM 2ND POWER OUTPUT
ABMK OVERALL WIDTH 5.000 INCHES NOMINAL
FEAT SPECIAL FEATURES CANNOT BE DAMAGED BY ANY SHORT CIRCUIT; INPUT UNDER/OVER VOLTAGE; OUTPUT OVERVOLTAGE; OUTPUT UNDER/OVER FREQUENCY; THERMAL OVERHEAT; REVERSE POLARITY; FAULT LIGHT INDICATOR
AYNH OPERATING AMBIENT TEMP RANGE -55.0/+71.0 DEG CELSIUS
AGAV END ITEM IDENTIFICATION B52C130F16 SIM INST