Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
9Y580 EDO CORPORATION DBA EDO NAVAL COMMAN

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO
ADAU BODY HEIGHT 38.0 MILLIMETERS NOMINAL
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCKPROOF AND FUNGUS PROOF AND VIBRATIONPROOF
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
AKPX POLE QUANTITY 3
THSD THREAD SERIES DESIGNATOR ISO M
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 200.0 AC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 3.5 AMPERES AC ALL LOCATIONS AND 3.5 AMPERES DC ALL LOCATIONS
CPRJ TRIP RELEASE METHOD THERMAL ALL LOCATIONS
ABXD BUSHING LENGTH 6.5 MILLIMETERS NOMINAL
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS AND 6000.0 DC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 15.0 MILLIMETERS NOMINAL
CQJX NOMINAL THREAD SIZE 12.0 MILLIMETERS
ADTV CASE MATERIAL PLASTIC
ADAQ BODY LENGTH 19.5 MILLIMETERS NOMINAL
CPRQ RESET METHOD MANUAL
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON
CQQR THREAD PITCH IN MILLIMETERS 1.25
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 12.8 MILLIMETERS NOMINAL
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
FEAT SPECIAL FEATURES BLACK PUSH BUTTON
ADAT BODY WIDTH 45.0 MILLIMETERS NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 6 SCREW
AGAV END ITEM IDENTIFICATION ALOFTS SONAR SYSTEM, MODEL 980 (V1)
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE