Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER AUTOTRANSFORME

Definition:

A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.

CAGE Information

Code Company
00144 ADC TELECOMMUNICATIONS INC. DIV ADC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY OUTPUT
ABTB MOUNTING HOLE DIAMETER 0.173 INCHES NOMINAL SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
TTQY TERMINAL TYPE AND QUANTITY 5 WIRE HOOK
CRBZ WINDING OPERATING CURRENT 1.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY INPUT
CWJS WINDING OPERATING VOLTAGE 26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT
AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
ADAT BODY WIDTH 1.625 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
AKNA INCLOSURE TYPE HERMETICALLY SEALED
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT
ADAQ BODY LENGTH 1.688 INCHES MAXIMUM
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAU BODY HEIGHT 2.375 INCHES MAXIMUM

Similar Parts

3-10603 , 310603 , 5950-00-854-7142 , 5950008547142 , 008547142