Part Number
Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | NATURAL |
STYL | STYLE DESIGNATOR | SHRINKABLE |
FLEX | FLEXIBILITY | FLEXIBLE |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 30.0 |
ABJH | TEMP RATING | -67.0 DEG CELSIUS AND 250.0 DEG CELSIUS |
AFZN | RECOVERED WALL THICKNESS | 0.012 INCHES NOMINAL |
CQBC | MINIMUM TENSILE STRENGTH | 2500 POUNDS PER SQUARE INCH AND 5000 POUNDS PER SQUARE INCH |
MATL | MATERIAL | PLASTIC, POLYTETRAFLUOROETHYLENE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 1500.0 VOLTS PER MIL /0.001 INCH/ |
AFZM | RECOVERED INSIDE DIAMETER | 0.063 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | CHEMICAL RESISTANT AND SOLVENT RESISTANT |
AFZL | EXPANDED INSIDE DIAMETER | 0.250 INCHES MINIMUM |