Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
058R3 | GE AVIATION SYSTEMS LLC DIV CUSTOMER |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.060 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.120 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.170 INCHES NOMINAL SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
TEST | TEST DATA DOCUMENT | 19623-007439 DRAWING |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABKW | OVERALL HEIGHT | 1.360 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
ABHP | OVERALL LENGTH | 2.700 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.710 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRMJ | WINDING POWER RATING | 270.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CBME | CUBIC MEASURE (NON-CORE) | 6.27 CUBIC INCHES |
CWJS | WINDING OPERATING VOLTAGE | 9.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 50.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 0.500 POUNDS |
CWJS | WINDING OPERATING VOLTAGE | 28.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |