Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
19587 KELVIN INDUSTRIES INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKNA INCLOSURE TYPE FULLY INCLOSED
AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 0.85 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY
CRMJ WINDING POWER RATING 102.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
ABTB MOUNTING HOLE DIAMETER 0.196 INCHES NOMINAL SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
ADAU BODY HEIGHT 2.250 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 3.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CBME CUBIC MEASURE (NON-CORE) 23.2 CUBIC INCHES
ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ADAT BODY WIDTH 2.562 INCHES NOMINAL
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
ABHP OVERALL LENGTH 4.031 INCHES NOMINAL
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AARD DUMMY TERMINAL QUANTITY (NON-CORE) 3
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OR 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CRMJ WINDING POWER RATING 100.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
TTQY TERMINAL TYPE AND QUANTITY 5 TAB, SOLDER LUG

Similar Parts