Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
71785 | CINCH CONNECTORS INC. |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.500 INCHES |
ABCS | TERMINAL ROW QUANTITY | 1 |
AMPS | CURRENT RATING IN AMPS | 10.0 |
ABGS | BASE THICKNESS | 0.281 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.375 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.172 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 4 SINGLE |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.875 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
CRNL | NONFEEDTHRU TERMINAL TYPE | 858 SINGLE |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1000.0 |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABGQ | BOARD OVERALL HEIGHT | 0.500 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.156 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.188 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
ABGN | BOARD OVERALL LENGTH | 2.219 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |