Part Number
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
MATT | MATERIAL | COPPER 1ST POSITION SHIELD BRAID, METALLIC CABLE |
MATT | MATERIAL | PLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET CABLE |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 4 SINGLES |
CXDC | ROUND CONDUCTOR SIZE | 12 AWG ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN ALLOY 1ST POSITION COATING CABLE |
ABJH | TEMP RATING | -65.0 DEG CELSIUS AND 150.0 DEG CELSIUS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 28 ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 37 ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION JACKET CABLE |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATT | MATERIAL | COPPER ALLOY 101 CORE CONDUCTOR ALL CONDUCTORS OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.302 INCHES NOMINAL |
AMQN | CONDUCTOR QUANTITY | 4 |
MATT | MATERIAL | PLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORS |