National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
6107W21P001 | 97424 | A | C | 1 | 5 | TX | AW | |
M39016/21-037P | 81349 | M | 2 | 2 | 3 | TX | ||
J432D-18WP | 11532 | A | C | 1 | 6 | TX | AF | |
M39016/21-037M | 81349 | M | E | 8 | 3 | TX | ||
4-32D18 | 11532 | A | C | 1 | 6 | ZZ | AC | |
MIL-PRF-39016/21 | 81349 | M | 4 | 1 | 4 | ZZ | ||
M39016/16-016M | 81349 | M | 5 | 9 | E | TX | ||
M39016/16-032M | 81349 | M | 5 | 9 | E | TX | ||
M39016/21-017M | 81349 | M | 5 | 9 | 3 | TX | ||
M39016/16-040P | 81349 | M | 5 | 9 | E | TX | ||
MIL-R-39016/21 | 81349 | M | 5 | 9 | 3 | TX |
CAGE Information
Code | Company |
---|---|
11532 | TELEDYNE TECHNOLOGIES INCORPORATED D |
97424 | AMETEK INC. DIV AEROSPACE & DEFENSE |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
AKDX | WINDING QUANTITY | 1 |
CRXH | TIME DELAY | 0.0075 SECONDS MAXIMUM FIXED RELEASE TIME |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/21 GOVERNMENT SPECIFICATION |
APCN | COIL QUANTITY | 1 |
CBBL | FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 10.9 MILLIAMPERES DC SINGLE WINDING |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
APNA | WINDING DC RESISTANCE RATING | 1.6 KILOHMS NOMINAL SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
APNP | DUTY TYPE | CONTINUOUS |
FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT; 0.500 IN. MINIMUM LEAD LG |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |
ABKW | OVERALL HEIGHT | 0.375 INCHES MAXIMUM |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 18.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |