Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
R0013514RA 35510 R 5 9 X XX
R0013514RA 24975 A 3 2 5 ZZ

CAGE Information

Code Company
24975 PRESTOLITE ELECTRIC INCORPORATED
35510 PRESTOLITE ELECTRIC INC

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ABMK OVERALL WIDTH 3.430 INCHES NOMINAL
APCN COIL QUANTITY 1
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.0 AMPERES DC RESISTIVE LOAD
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 300.0 MILLIAMPERES DC ALL WINDINGS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
AKDX WINDING QUANTITY 3
ZZZV FSC APPLICATION DATA (NON-CORE) ELECTRICAL GROUP,DIESEL ENGINE
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.266 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
ABHP OVERALL LENGTH 4.750 INCHES NOMINAL
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 24.0 DC
ABKW OVERALL HEIGHT 2.060 INCHES NOMINAL
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF AND WATERTIGHT

Similar Parts

R0013514RA , R0013514RA , 5945-00-636-8810 , 5945006368810 , 006368810 , R0013514RA , R0013514RA ,