National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
666093-500 | 12436 | A | 5 | 2 | 5 | TX | ||
5950002266291 | SCY13 | A | 5 | 9 | 9 | YP | ||
SM-C-502071 | 80063 | A | 3 | 2 | A | TX | ||
398696 | 80045 | A | 5 | 2 | 5 | 9Z | ||
W-5474 | 08715 | A | 5 | 9 | 5 | CL | ||
A5045 | 05584 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
05584 | AUTODYNE MANUFACTURING CO. INC. |
12436 | BAE SYSTEMS NATIONAL SECURITY SOLUTI |
SCY13 | E.C.A ETABLISSEMENT CENTRAL DES APPR |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
80045 | L-3 COMMUNICATIONS CINCINNATI ELECTR |
08715 | CEN ELECTRONICS A DIV OF CHLORIDE PO |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACZB | FREQUENCY RATING | 1.2 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 1.2 KILOHERTZ NOMINAL SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 350.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 500.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET AND 2 WIRE LEAD AND 3 WIRE HOOK |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.30 DC MINOR WET SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 27.00 DC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AEHZ | MAXIMUM OPERATING TEMP | 110.0 DEG CELSIUS |
CWJS | WINDING OPERATING VOLTAGE | 50.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |