National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
REACTOR
Definition:
A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
63331 | 24930 | A | 3 | 2 | E | TX | ||
38930 | 73386 | A | 5 | 2 | 5 | TX | ||
L-18824 | 95970 | A | 5 | 9 | 5 | TX | ||
L-18824 | 53854 | A | C | 1 | 5 | ZZ | 9X |
CAGE Information
Code | Company |
---|---|
24930 | ITT CORPORATION DBA ITT ELECTRONICS |
73386 | FREED TRANSFORMER COMPANY |
95970 | MTE CORP MILWAUKEE TRANSFORMER CO |
53854 | MAGNESPEC INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ACZB | FREQUENCY RATING | 2.4 KILOHERTZ NOMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 69.0 DEG CELSIUS |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SOLDER STUD |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ABMK | OVERALL WIDTH | 2.000 INCHES MAXIMUM |
ACYV | INDUCTANCE RATING | 3.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAU | BODY HEIGHT | 2.062 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 2.437 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABHP | OVERALL LENGTH | 2.125 INCHES MAXIMUM |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 SINGLE COMPONENT SINGLE WINDING |