National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
MOTOR , ALTERNATING CURRENT

Definition:

A MOTOR WHICH IS DESIGNED FOR OPERATION FROM AN ALTERNATING CURRENT SOURCE. SEE ALSO MOTOR, CONTROL.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
L3505 05472 A 3 2 5 CX
403742-001 93742 A 5 9 5 CX
403743-001 93742 A 5 2 5 CX
80-7684 30554 A 5 9 A CX
00781568100295 05472 A 5 1 U ZZ

CAGE Information

Code Company
05472 BALDOR ELECTRIC CO
93742 ENGINEERED ELECTRIC COMPANY DBA DRS
30554 DEPARTMENT OF DEFENSE PROJECT MANAGE

Federal Supply Class

Title

MOTORS, ELECTRICAL

Inclusions:

Exclusions:

EXCLUDES STARTING MOTORS FOR ENGINES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AAJU OVERALL LENGTH 14.500 INCHES
ANPZ INCLOSURE FEATURE TOTALLY INCLOSED
ABRV KEYWAY DEPTH 0.1250 INCHES NOMINAL SINGLE END
CWFX ROTOR SPEED RATING IN RPM 1140.0 SINGLE FULL LOAD
AAJT OVERALL HEIGHT 9.000 INCHES
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 SLOT
CWDT NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.000 INCHES
CWFY NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 4.875 INCHES
AFYS KEYWAY LENGTH 1.8800 INCHES NOMINAL SINGLE END
FAAZ PHASE SINGLE INPUT
BKPQ INCLOSURE SPECIFICATION NEMA
AXCP WINDING TYPE INDUCTION-TWO VALUE CAPACITOR SPLIT PHASE
AKPS DUTY CYCLE CONTINUOUS
ABRR KEYWAY WIDTH 0.1900 INCHES NOMINAL SINGLE END
AXGY MOUNTING METHOD FIXED BASE
CNXS POWER RATING 0.5000 HORSEPOWER OUTPUT
BFMF COOLING METHOD FAN COOLED
BKPB CURRENT RATING METHOD LOAD
AAJV OVERALL WIDTH 6.500 INCHES
CBBL FEATURES PROVIDED HORIZONTAL MOUNTING POSITION
CNMM FRAME SIZE DESIGNATION 56

Similar Parts