Part Number
Part Number:
NSN:
NIIN:
Item Name:
FILTER , LOW PASS
Definition:
AN ITEM DESIGNED TO PASS ALL FREQUENCIES BELOW A SPECIFIED FREQUENCY. EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABHP | OVERALL LENGTH | 2.875 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+2000.0 |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.600 INCHES NOMINAL |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CAPTIVE SCREWS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 125.0 MINIMUM BLANK AND 2.0 MAXIMUM BLANK AND 2.0 MAXIMUM BLANK AND 135.0 MINIMUM BLANK |
CQRG | BODY MATERIAL | METAL |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 100.5 HERTZ BLANK |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 2.0 BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN OUTPUT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
ADAT | BODY WIDTH | 0.600 INCHES NOMINAL |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN GROUND |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
ADAQ | BODY LENGTH | 2.250 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -55.0/+100.0 DEG CELSIUS |
ADAU | BODY HEIGHT | 0.600 INCHES MAXIMUM |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 200.00 HERTZ BLANK AND 1.00 HERTZ BLANK AND 2.50 KILOHERTZ BLANK AND 5.00 KILOHERTZ BLANK |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.00 HERTZ BLANK AND 200.00 HERTZ BLANK |