Part Number
Part Number:
NSN:
NIIN:
Item Name:
FILTER , BAND PASS
Definition:
AN ITEM DESIGNED TO PASS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO SUPPRESS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, OR A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHCH | AVERAGE POWER RATING PER FUNCTION | 2.0 WATTS BLANK |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 1.4 GIGAHERTZ BLANK AND 1.6 GIGAHERTZ BLANK |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 49956 |
ABHP | OVERALL LENGTH | 5.062 INCHES MINIMUM AND 6.062 INCHES MAXIMUM |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.44 GIGAHERTZ BLANK AND 1.57 GIGAHERTZ BLANK |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK |
CQRG | BODY MATERIAL | METAL |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 2.0 BLANK |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 49956 |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT |
AHBP | INPUT TERMINAL IDENTIFICATION | SMA-FEMALE |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 80.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 3.0 MAXIMUM BLANK AND 80.0 MINIMUM BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK |
ADAR | BODY OUTSIDE DIAMETER | 0.510 INCHES MAXIMUM |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.3 BLANK |
STYL | STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AKNA | INCLOSURE TYPE | ENCASED |
AHBT | OUTPUT TERMINAL IDENTIFICATION | SMA-MALE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
AFGA | OPERATING TEMP RANGE | +0.0/+65.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 1.5 GIGAHERTZ BLANK |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.57 GIGAHERTZ BLANK AND 1.44 GIGAHERTZ BLANK AND 1.23 GIGAHERTZ BLANK AND 1.78 GIGAHERTZ BLANK |