Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
71785 | CINCH CONNECTORS INC. |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 4.0 |
AMPS | CURRENT RATING IN AMPS | 30.0 |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 8 SINGLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.500 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABGP | BOARD OVERALL WIDTH | 1.625 INCHES |
ABGN | BOARD OVERALL LENGTH | 5.468 INCHES |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.219 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.875 INCHES |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.562 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.062 INCHES |
CBBL | FEATURES PROVIDED | MARKER STRIP |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABGQ | BOARD OVERALL HEIGHT | 0.875 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.203 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.209 INCHES |
ABGS | BASE THICKNESS | 0.500 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 8 SINGLE |
AAQL | BODY STYLE | BARRIER TYPE |