Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
METER , MULTIPLE SCALE

Definition:

AN INSTRUMENT WITH TWO OR MORE DIFFERENT SCALES MEASURING DIFFERENT QUANTITIES, USUALLY ON A SINGLE CALIBRATED DIAL OR DIGITAL READOUT DISPLAY. IT IS INTENDED FOR VISUALLY MONITORING AN OPERATION. THE METER MUST BE PERMANENTLY CONNECTED INTO AN APPROPRIATE ELECTRONIC CIRCUIT. EXCLUDES: AMMETER; VOLTMETER; WATTMETER AND METER, ELECTRICAL FREQUENCY.

CAGE Information

Code Company
0BHF9 PRIME TECHNOLOGY LLC

Federal Supply Class

Title

ELECTRICAL AND ELECTRONIC PROPER

Inclusions:

INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.

Exclusions:

EXCLUDES RADIAC EQUIPMENT

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
APPN ACCURACY IN PERCENT -2.0/+2.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES
AWZJ POWER SOURCE EXTERNAL
FEAT SPECIAL FEATURES RUGGEDIZED AND HORIZONTAL MOUNTING
APSN PANEL FOR WHICH DESIGNED (NON-CORE) NONMAGNETIC
AMQY INSTALLATION DESIGN PANEL
ABKW OVERALL HEIGHT 1.525 INCHES MAXIMUM
BMNG METER BODY HEIGHT BEHIND MOUNTING FLANGE 1.525 INCHES MAXIMUM
ABTB MOUNTING HOLE DIAMETER 0.138 INCHES NOMINAL
CBBL FEATURES PROVIDED KNIFE EDGE POINTER AND MAGNETIC SHIELD AND SELF-ILLUMINATION FACILITY AND ZERO ADJUSTER
NHCF NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
STYL STYLE DESIGNATOR RECTANGULAR FLUSH MTG
BHDC SCALE GRADUATION TYPE NONLINEAR SINGLE INDICATOR ALL RANGES
AMKD INDICATOR TYPE DIAL W/POINTER
BLSB SCALE SELECTION METHOD TERMINAL
APST METER DEPTH BEHIND MOUNTING FLANGE 2.525 INCHES MINIMUM AND 2.603 INCHES MAXIMUM
ANRL MOUNTING ARRANGEMENT STYLE FOUR HOLE/STUD RECTANGULAR/SQUARE
ABMK OVERALL WIDTH 4.234 INCHES MAXIMUM
CTQL MOVEMENT SUSPENSION METHOD JEWEL PIVOT BASE
AAPB DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS 1500.0
APMM DIAL SCALE MARKING COLOR BLACK SINGLE INDICATOR ALL RANGES
BHMW MEASUREMENT RANGE +0.0/+800.0 KILOWATTS SINGLE INDICATOR 4TH RANGE
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.799 INCHES MINIMUM AND 3.811 INCHES MAXIMUM
ADZC ENVIRONMENTAL PROTECTION VIBRATION RESISTANT AND SHOCK RESISTANT AND WATERTIGHT
MATT MATERIAL ALUMINUM
AQFY BACKGROUND COLOR WHITE SINGLE INDICATOR ALL RANGES
BHSX CIRCUIT CONSTRUCTION TYPE (NON-CORE) NONELECTRONIC
SFTT SURFACE TREATMENT ENAMEL
AQEC MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
AACT CIRCUIT CURRENT FOR WHICH DESIGNED DC
BHMW MEASUREMENT RANGE -10.0/+0.0 DECIBELS ABOVE OR BELOW ONE MILLIWATT SINGLE INDICATOR 2ND RANGE
BHMW MEASUREMENT RANGE +0.0/+350.0 KILOWATTS SINGLE INDICATOR 3RD RANGE
CTTD CIRCUIT ATTACHMENT METHOD AND QUANTITY 2 SOLDER LUG
SPCL SPECIAL TEST FEATURES DRAWING IAW MIL-D-1000; SHOCK AND MOISTURE RESISTANT IAW MIL-STD-202; MARK IAW MIL-STD-130
ZZZV FSC APPLICATION DATA TEST SET,ELECT. EQUIP.
MARK SPECIAL MARKINGS TRACK PK PWR ON 0 TO 800 KW RANGE; CAPT./GUID. PK PWR ON 0 TO 350 KW RANGE; PULSE SIM. ON DBM RANGES
ABHP OVERALL LENGTH 3.790 INCHES MAXIMUM
BHMW MEASUREMENT RANGE -20.0/-10.0 DECIBELS ABOVE OR BELOW ONE MILLIWATT SINGLE INDICATOR 1ST RANGE
SUPP SUPPLEMENTARY FEATURES 18 OHM UPPER AND 135 OHM LOWER RANGE RESISTANCES
ANTG SENSITIVITY RATING 1.85 MILLIAMPERES AND 18.5 MILLIAMPERES
ASSS POINTER COLOR BLACK SINGLE INDICATOR ALL RANGES
APSY METER BODY WIDTH BEHIND MOUNTING FLANGE 3.450 INCHES MAXIMUM
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.744 INCHES MINIMUM AND 0.756 INCHES MAXIMUM

Similar Parts