Part Number
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
CAGE Information
Code | Company |
---|---|
15605 | EATON CORP OPNS & TECHNICAL CENTER |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 50.00 DC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED HOLE |
ABTB | MOUNTING HOLE DIAMETER | 0.844 INCHES NOMINAL SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRBZ | WINDING OPERATING CURRENT | 70.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
ADAQ | BODY LENGTH | 1.938 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
ABHY | TURN QUANTITY | 21 SINGLE COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 0.002 SINGLE COMPONENT SINGLE WINDING |
ADAR | BODY OUTSIDE DIAMETER | 2.125 INCHES NOMINAL |