Part Number
Definition:
AN ELECTRICAL FITTING WITH ELECTRICAL CONTACTS CONSTRUCTED TO BE AFFIXED TO THE END OF A CABLE, CONDUIT, COAXIAL LINE, CORD, WIRE (INCLUDES PRINTED/ETCHED), PRINTED WIRING BOARD, OR THE LIKE FOR CONVENIENCE IN JOINING WITH ANOTHER ELECTRICAL CONNECTOR(S) OR PRINTED WIRING BOARD. IT IS DESIGNED TO BE MOUNTED ON A BULKHEAD, CHASSIS, PANEL, WALL, PRINTED WIRING BOARD, OR THE LIKE. EXCLUDES LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (AS MODIFIED) AND SOCKET, PLUG-IN ELECTRONIC COMPONENTS. SEE ALSO WIRING HARNESS (AS MODIFIED) AND CABLE ASSEMBLY (AS MODIFIED). FOR ITEMS WITH TERMINATION WIRES OF MORE THAN FOUR INCHES IN LENGTH, SEE LEAD ASSEMBLY, ELECTRICAL. FOR ITEMS WITHOUT INSERTS, SEE SHELL, ELECTRICAL CONNECTOR.
CAGE Information
Code | Company |
---|---|
54206 | CUBIC SIMULATION SYSTEMS INC. |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAQL | BODY STYLE | WALL TYPE |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | "3,10-30" SINGLE MATING END |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 30.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 250.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AFQW | MATING END QUANTITY | 1 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.807 INCHES MINIMUM AND 1.817 INCHES MAXIMUM |
CXCL | INCLUDED CONTACT TYPE | L-SOCKET SINGLE MATING END 1ST CONTACT GROUPING |
CSCF | TERMINAL TYPE | SCREW SINGLE MATING END ALL CONTACT GROUPINGS |
CQTM | TERMINAL LOCATION | FRONT SINGLE MATING END 1ST CONTACT GROUPING |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END 2ND CONTACT GROUPING |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 250.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AAJF | THREAD DIRECTION | RIGHT-HAND |
TEST | TEST DATA DOCUMENT | 81348-W-C-596 SPECIFICATION |
AFRN | POLARIZATION METHOD | CONTACT |
ADZC | ENVIRONMENTAL PROTECTION | HEAT RESISTANT |
AFQR | THREADED DEVICE TYPE | MOUNTING HOLE |
CXCL | INCLUDED CONTACT TYPE | FLAT SOCKET SINGLE MATING END 2ND CONTACT GROUPING |
THSD | THREAD SERIES DESIGNATOR | UNC |
AAJD | THREAD CLASS | 2A |
CXCG | INCLUDED CONTACT QUANTITY | 2 SINGLE MATING END 2ND CONTACT GROUPING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.276 INCHES MINIMUM AND 3.286 INCHES MAXIMUM |
CXCG | INCLUDED CONTACT QUANTITY | 1 SINGLE MATING END 1ST CONTACT GROUPING |
ZZZK | SPECIFICATION/STANDARD DATA | 81348-W-C-596/33 GOVERNMENT SPECIFICATION |
AFQZ | CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |