Part Number
Part Number:
NSN:
NIIN:
Item Name:
COMPRESSOR UNIT , RECIPROCATING
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED RECIPROCATING COMPRESSOR(S) AND A PRIME MOVER(S). FOR ITEMS WITH ADDITIONAL EQUIPMENT WHICH EXTENDS THE FUNCTION OF THE UNIT BEYOND THE DELIVERY OF COMPRESSED AIR OR GAS, SEE PNEUMATIC TOOL AND COMPRESSOR OUTFIT, OR MORE SPECIFIC NAMES, AS APPLICABLE. EXCLUDES AUXILIARY SET, ENGINE DRIVEN.
CAGE Information
Code | Company |
---|---|
28953 | RIX INDUSTRIES |
Federal Supply Class
Title
COMPRESSORS AND VACUUM PUMPS
Inclusions:
INCLUDES TRUCK MOUNTED AND TRAILER MOUNTED COMPRESSORS.
Exclusions:
EXCLUDES REFRIGERATION COMPRESSORS (FSC 4130).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AAXV | UNLOADER TYPE | AUTOMATIC |
AAXL | DISCHARGE FLOW RATE | 100.000 CUBIC FEET PER MINUTE |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AAXP | COOLING SYSTEM DESIGN | MIXED |
AAXM | DISCHARGE PRESSURE | 125.000 POUNDS PER SQUARE INCH GAGE |
AAZA | SILENCER TYPE | INLET |
AAXJ | DUTY CYCLE IN PERCENT | 100 |
CQJY | CURRENT TYPE AND RATING IN AMPS | 40.0 AC |
BPRZ | SAFETY DEVICE TYPE | LOW PRESSURE SHUTDOWN SWITCH AND LOW PRESSURE OIL SHUTDOWN SWITCH AND BELOW PRESSURE CUTOUT AND HIGH PRESSURE SHUTDOWN SWITCH AND LOW PRESSURE SHUTOFF VALVE AND HIGH TEMPERATURE SHUTDOWN SWITCH AND HIGH PRESSURE CUTOUT AND RELIEF VALVE |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AAXU | GAS COOLING EQUIPMENT TYPE | LIQUID TYPE AFTERCOOLER AND LIQUID TYPE INTERCOOLER |
FAAZ | PHASE | THREE |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 440.0 AC |
AAXR | COMPRESSOR COOLING MEDIUM | FRESH WATER AND SALT WATER |
AAYA | CYLINDER ARRANGEMENT STYLE | VERTICAL DESIGN |
AAXK | GAS FOR WHICH DESIGNED | AIR |
AAXG | COMPRESSOR QUANTITY | 1 |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAXZ | CYLINDER QUANTITY | 2 |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AAXX | MOUNTING TYPE | BASE |
AAYD | STAGE QUANTITY | 2 |
AAXQ | COMPRESSED GAS COOLING MEDIUM | FRESH WATER |
AAXY | RECIPROCATING COMPRESSOR DESIGN | SINGLE ACTING |