Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
94271 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 4 SINGLE |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.750 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-19833,TYPE GDI-30F MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 4 SINGLE |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.625 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.234 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.875 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.930 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.266 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.030 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 597 SINGLE |
ABGP | BOARD OVERALL WIDTH | 2.000 INCHES |
MATT | MATERIAL | PLASTIC DIALLYL PHTHALATE BOARD AND GLASS FIBER BOARD |
ABGN | BOARD OVERALL LENGTH | 4.906 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1800.0 |
AMPS | CURRENT RATING IN AMPS | 70.0 |
ABGS | BASE THICKNESS | 0.500 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |