Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
D1870 |
ROCKWELL-COLLINS DEUTSCHLAND GESCHAE |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 SINGLE LOCATION |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
CQQR |
THREAD PITCH IN MILLIMETERS |
0.50 |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
FREQ |
FREQUENCY IN HERTZ |
50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 22.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
THSD |
THREAD SERIES DESIGNATOR |
ISO M |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 THREADED STUD |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC SINGLE LOCATION |
CQJX |
NOMINAL THREAD SIZE |
3.0 MILLIMETERS |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
PKWT |
UNPACKAGED UNIT WEIGHT |
3.700 OUNCES |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.475 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC SINGLE LOCATION |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
ADAQ |
BODY LENGTH |
2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
ADAT |
BODY WIDTH |
0.750 INCHES MAXIMUM |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SALT WATER RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES AC SINGLE LOCATION |
Similar Parts