Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
FAN , VANEAXIAL

Definition:

A NONPOSITIVE DISPLACEMENT MECHANICAL DEVICE WITH GUIDE VANES AND HAVING AN AXIAL FAN IMPELLER(S) INCLOSED WITHIN A TUBULAR HOUSING. IT IS DESIGNED PRIMARILY FOR DUCT INSTALLATION TO MOVE AIR OR GAS AXIALLY OVER A WIDE RANGE OF VOLUMES AND PRESSURES.

CAGE Information

Code Company
09519 NEW PHILADELPHIA FAN CO BUFFALO FORG

Federal Supply Class

Title

FANS, AIR CIRCULATORS, AND BLOWE

Inclusions:

INCLUDES WALL TYPE FANS; PEDESTAL TYPE FANS; HOUSEHOLD TYPE AND ATTIC TYPE EXHAUST FANS; FLOOR FANS; FORGED DRAFT EXHAUST AND DISPOSAL KITS; FANS, AIR CIRCULATORS, AND BLOWER EQUIPMENT, WHETHER DESIGNATED AS "INDUSTRIAL" OR "NONINDUSTRIAL" BY APPLICATION AND/OR USE.

Exclusions:

EXCLUDES COMBINATION HEATER-FANS (FSC 4520).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ADNK FLOW DIRECTION INWARD
ABBB SPEED ADJUSTMENTS TWO SPEED
FREQ FREQUENCY IN HERTZ 60.0
AKNA INCLOSURE TYPE FULLY INCLOSED
SFTT SURFACE TREATMENT CHROMATE ZINC HOUSING OUTSIDE OR PRIMER HOUSING OUTSIDE
STYL STYLE DESIGNATOR FIXED
MATT MATERIAL STEEL HOUSING
AXHR MOUNTING FACILITY TYPE AND QUANTITY 52 UNTHREADED HOLE
AKDJ PRIME MOVER TYPE ELECTRIC MOTOR
AEQC OPERATING SPEED AT RATED CAPACITY IN RPM 875.0 AND 1750.0
MDCL MATERIAL DOCUMENT AND CLASSIFICATION ASTM A36 ASSN STD SINGLE MATERIAL RESPONSE HOUSING
FAAZ PHASE THREE
CSBH VOLTAGE IN VOLTS AND CURRENT TYPE 440.0 AC
ABRY LENGTH 53.500 INCHES NOMINAL
AGBD ELECTRICAL CONNECTION TYPE TERMINAL BOX
CQKX AIR FLOW RATE 30625.0 CUBIC FEET PER MINUTE NOMINAL AND 61250.0 CUBIC FEET PER MINUTE NOMINAL
AYSY ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
CWLX HOUSING INSIDE DIAMETER 48.312 INCHES NOMINAL
SFTT SURFACE TREATMENT CHROMATE ZINC HOUSING INSIDE OR PRIMER HOUSING INSIDE

Similar Parts

E1-7492-2/MAS48C7 , E174922MAS48C7 , 4140-01-264-7459 , 4140012647459 , 012647459