Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
24727 SEACON BRANTNER & ASSOCIATES DBA SEA

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AAJD THREAD CLASS 2A SINGLE MOUNTING FACILITY
CSQJ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 1.890 INCHES NOMINAL
ABKW OVERALL HEIGHT 3.250 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
CQYJ MOUNTING FACILITY PATTERN TRIANGLE SINGLE MOUNTING FACILITY
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 THREADED STUD SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 2C
CMLP THREAD QUANTITY PER INCH 32 SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 0.980 INCHES NOMINAL

Similar Parts

E1176-1 , E11761 , 5945-00-923-2530 , 5945009232530 , 009232530