Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
24727 SEACON BRANTNER & ASSOCIATES DBA SEA

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.937 INCHES NOMINAL SINGLE MOUNTING FACILITY
AAJD THREAD CLASS 2A SINGLE MOUNTING FACILITY
THSD THREAD SERIES DESIGNATOR UNC SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 2.500 INCHES NOMINAL
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
APCN COIL QUANTITY 1
ABMK OVERALL WIDTH 1.370 INCHES NOMINAL
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES DC RESISTIVE LOAD
APNP DUTY TYPE CONTINUOUS
TTQY TERMINAL TYPE AND QUANTITY 14 PIN ALL FUNCTIONS
ABKW OVERALL HEIGHT 1.560 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED STUD SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 30.0 DC
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY

Similar Parts

E233 , E233 , 5945-00-829-0060 , 5945008290060 , 008290060