Part Number
Part Number:
NSN:
NIIN:
Item Name:
FILTER , BAND PASS
Definition:
AN ITEM DESIGNED TO PASS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO SUPPRESS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, OR A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
12598 | R L C ELECTRONICS INC. |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 BLANK |
AHCH | AVERAGE POWER RATING PER FUNCTION | 50.0 WATTS BLANK |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD OUTPUT |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 BLANK |
ADAU | BODY HEIGHT | 3.880 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+33.0 |
ADAQ | BODY LENGTH | 5.750 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.160 INCHES NOMINAL |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM BLANK AND 50.0 MAXIMUM BLANK |
CQRG | BODY MATERIAL | METAL |
CBBL | FEATURES PROVIDED | MOUNTING BRACKET |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 29.00 MEGAHERTZ BLANK AND 31.00 MEGAHERTZ BLANK |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 29.00 MEGAHERTZ BLANK AND 31.00 MEGAHERTZ BLANK AND 27.90 MEGAHERTZ BLANK AND 32.10 MEGAHERTZ BLANK |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD INPUT |
AHBP | INPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
AKNA | INCLOSURE TYPE | ENCASED |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 30.0 MEGAHERTZ BLANK |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 12598 |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 6.125 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.280 INCHES MAXIMUM |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 29.0 MEGAHERTZ BLANK AND 31.0 MEGAHERTZ BLANK |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 12598 |
AFGA | OPERATING TEMP RANGE | +0.0/+50.0 DEG CELSIUS |
AHBT | OUTPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |