Part Number
Part Number:
NSN:
NIIN:
Item Name:
PUMP UNIT , CENTRIFUGAL
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
CAGE Information
Code | Company |
---|---|
03950 | NAVAL INVENTORY CONTROL POINT MECHAN |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
FREQ | FREQUENCY IN HERTZ | 60.0 |
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
CSYL | PRIME MOVER POWER RATING | 265.000 HORSEPOWER |
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 7 |
AENC | PUMP QUANTITY | 1 |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
FAAZ | PHASE | THREE |
AHZA | PUMPING ELEMENT OPERATING POSITION | VERTICAL |
AMPS | CURRENT RATING IN AMPS | 324.9 |
AAXH | PRIME MOVER QUANTITY | 1 |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 3600.0 REVOLUTIONS PER MINUTE |
ACKL | MEDIA FOR WHICH DESIGNED | WATER, FRESH |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | ITEMS THAT SUPPORT A LEVEL I OR SUBSAFE CRITICAL SYSTEM/COMPONENT THAT HAS UNDERGONE QUALITY ASSURANCE DURING THE ACQUISITION PROCESS AND REQUIRES OBJECTIVE QUALITY EVIDENCE (OQE) TRACEABLE TO PERMANENT MARKING ON THE MATERIALAS DIFFERENTIATED BY PRIME MOVER TYPE REQUIREMENT,ELECTRIC MOTOR MFG GEN |
ACDC | CURRENT TYPE | AC |
AAYD | STAGE QUANTITY | 7 |
AHZE | CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
ELEC | VOLTAGE IN VOLTS | 440.0 |