Part Number
Part Number:
NSN:
NIIN:
Item Name:
CONTACTOR , MAGNETIC
Definition:
AN ITEM CONSISTING OF CONTACTS, A MAGNETIC CORE, AND A COIL WITH OR WITHOUT INCLOSURE WHICH IS USED TO REPEATEDLY ESTABLISH AND BREAK A CIRCUIT. THE ITEM DOES NOT PROVIDE OVERLOAD PROTECTION AND IS NOT USED IN LINE TO CONTROL ANY OTHER ELECTRICAL CONTROLS. EXCLUDES RELAY, ELECTROMAGNETIC AND STARTER, MOTOR.L CIRCUIT. EXLUDES RELAY, ELECTRO-MAGNETIC AND STARTER, MOTOR.
CAGE Information
Code | Company |
---|---|
58657 | LEACH INTERNATIONAL CORPORATION DBA |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 3.130 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | C-130 AMP |
ABHP | OVERALL LENGTH | 2.500 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 2.500 INCHES NOMINAL |
ACUT | DIRECT CURRENT RATING IN AMPS | 50.0 AND 20.0 |
ZZZK | SPECIFICATION/STANDARD DATA | 88277-5D0305 NATIONAL STD/SPEC |
ACYR | DC VOLTAGE RATING | 28.0 VOLTS NOMINAL |
ALGC | MOUNTING CONFIGURATION | 4 X 0.170 INCH SLOTTED HOLES IN EACH CORNER |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CONTACTOR, 50A DC/60A AC, 3PDT W/AUX CONT, HERMETICALLY SLD |
ANDX | AMBIENT TEMP | -55.0 DEG CELSIUS AND 71.0 DEG CELSIUS |