Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
CAGE Information
Code | Company |
---|---|
03508 | GENERAL ELECTRIC CO SEMI-CONDUCTOR P |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 8.0 |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -27.2/+27.2 10TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 30.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.9/+20.9 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.4/+18.4 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.9 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -24.5/+24.5 9TH RESISTANCE-TEMPERATURE POINT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
ADAQ | BODY LENGTH | 0.500 INCHES NOMINAL |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.6 MEGOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.48 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.96 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 12.1 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.9 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT |
STYL | STYLE DESIGNATOR | ROD |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 137.2 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.3/+10.3 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.5/+12.5 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.3/+16.3 2ND RESISTANCE-TEMPERATURE POINT |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 975.0 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.3/+16.3 6TH RESISTANCE-TEMPERATURE POINT |
ABDN | TERMINAL SURFACE TREATMENT | SOLDER |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 22.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -10.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 70.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
ADAR | BODY OUTSIDE DIAMETER | 0.200 INCHES NOMINAL |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.5 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.7/+13.7 3RD RESISTANCE-TEMPERATURE POINT |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 62.0 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
CQWD | ZERO POWER RESISTANCE | 75.000 KILOHMS |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -21.4/+21.4 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 30.0 |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 10.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |