Part Number
Part Number:
NSN:
NIIN:
Item Name:
BACKSHELL , ELECTRICAL CONNECTOR
Definition:
AN ITEM SPECIFICALLY DESIGNED TO BE PLACED AROUND THAT PORTION OF A CONNECTOR, RECEPTABLE, ELECTRICAL OR CONNECTOR, PLUG, ELECTRICAL WHICH CONTAINS THE FACILITIES FOR ATTACHING WIRES OR CABLES. IT MAY BE DESIGNED TO PROVIDE THE NECESSARY ACCOMODATIONS BETWEEN AN ELECTRICAL CABLE CLAMPING DEVICE AND AN ELECTRICAL CONNECTOR SHELL, OR IT MAY INCLUDE THE CLAMPING DEVICE. IT MAY BE USED FOR SHIELDING AGAINST ELECTRICAL INTERFERENCE, MECHANICAL INJURY, OR PHYSICAL DAMAGE DUE TO ENVIRONMENTAL CONDITIONS.
CAGE Information
Code | Company |
---|---|
07418 | JOSLYN SUNBANK COMPANY LLC |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABFF | FURNISHED ITEMS | COVER W/CHAIN |
STYL | STYLE DESIGNATOR | HOOD, SIDE OPENING W/CLAMP |
AGTW | CABLE OPENING DIAMETER | 0.438 INCHES MINIMUM AND 0.750 INCHES MAXIMUM |
AAJF | THREAD DIRECTION | RIGHT-HAND |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
SURF | SURFACE TREATMENT | CADMIUM |
MATT | MATERIAL | ALUMINUM ALLOY |
THSD | THREAD SERIES DESIGNATOR | UNC |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.040 INCHES MINIMUM AND 2.050 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.625 INCHES MAXIMUM |
AKRD | CABLE OPENING QUANTITY | 1 |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.807 INCHES MINIMUM AND 0.817 INCHES MAXIMUM |
AAJD | THREAD CLASS | 2B |
CMLP | THREAD QUANTITY PER INCH | 32 |
ALJP | SIZE DESIGNATION | 80 |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
ABKW | OVERALL HEIGHT | 4.250 INCHES NOMINAL |