Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
51181 KEYTRONICS INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 700.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 9 TAB, SOLDER LUG
CRBZ WINDING OPERATING CURRENT 35.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 6.55 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 27.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.101 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CBME CUBIC MEASURE (NON-CORE) 8.5 CUBIC INCHES
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 600.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
ABKW OVERALL HEIGHT 1.889 INCHES NOMINAL
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
ABMK OVERALL WIDTH 1.834 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 39.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
ABHP OVERALL LENGTH 2.454 INCHES NOMINAL
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.283 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP

Similar Parts