Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
96253 | TRANSFORMER TECHNICIANS INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ADAU | BODY HEIGHT | 4.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.469 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.531 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 8 TAB, SOLDER LUG |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 6.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 65.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.969 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.031 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
ADAQ | BODY LENGTH | 2.969 INCHES MINIMUM AND 3.031 INCHES MAXIMUM |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |