Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
59782 | COMMUNICATIONS & POWER INDUSTRIES LL |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABMK | OVERALL WIDTH | 3.000 INCHES NOMINAL |
AJDB | POWER RATING | 1.000 KILOWATTS AVERAGE |
AFGQ | FREQUENCY RANGE RATING | +8.900/+9.400 GIGAHERTZ |
ABPM | BODY DIAMETER | 3.000 INCHES NOMINAL |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.15 |
ABHP | OVERALL LENGTH | 7.000 INCHES NOMINAL |
AKSA | WAVEGUIDE FLANGE DESIGNATION | AUG-1358/U |
BFMF | COOLING METHOD | FORCED LIQUID |
AAXT | COOLING SYSTEM COOLANT FLOW RATE | 0.3 GALLONS PER MINUTE |
ARNH | OPERATING POSITION | HORIZONTAL |
STYL | STYLE DESIGNATOR | WAVEGUIDE MOUNTED |
ACYW | IMPEDANCE RATING IN OHMS | NOT RATED |
AWNJ | COOLANT CHAMBER PRESSURE | 100.0 POUNDS PER SQUARE INCH GAGE |
AWNL | INPUT COOLANT TEMP | 30.0 DEG CELSIUS |
AKRZ | TERMINATION TYPE | WAVEGUIDE FLANGE |
AWNC | INTERNAL OPERATING PRESSURE | 15.0 POUNDS PER SQUARE INCH GAGE |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +8.900/+9.400 GIGAHERTZ |