Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
COIL , ELECTRICAL

Definition:

AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..

CAGE Information

Code Company
08068 MCCARRON ELECTRIC CO

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CRGS DC RESISTANCE RATING IN OHMS 0.080 SINGLE COMPONENT SINGLE WINDING
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.780 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
TTQY TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG
AKDX WINDING QUANTITY 1 SINGLE COMPONENT
ABTB MOUNTING HOLE DIAMETER 0.193 INCHES MAXIMUM SINGLE GROUP
ABKW OVERALL HEIGHT 1.280 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABMK OVERALL WIDTH 1.250 INCHES MAXIMUM
ABHP OVERALL LENGTH 2.190 INCHES MAXIMUM
ACZR CORE CONSTRUCTION S0LID SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 2 1ST GROUP

Similar Parts

M-5023 , M5023 , 5950-01-111-9993 , 5950011119993 , 011119993