Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , TOGGLE
Definition:
A SWITCH WHICH IS EXTERNALLY ACTUATED BY A LEVER AND WHOSE CONTACTS OPEN AND CLOSE WITH AN INSTANTANEOUS (SNAP) ACTION; INCLUDES ITEMS HAVING ONE OR MORE MOMENTARY POSITIONS. INCLUDES SWITCHES (SNAP ACTION) WHICH USE MERCURY TO BRIDGE CONTACTS, AND ASSEMBLAGES OF COMPLETE SWITCHES (SNAP ACTION) HAVING COMMON ACTUATORS. EXCLUDES SWITCH, LEVER; SWITCH, ROTARY; SWITCH, KNIFE; SWITCH, SENSITIVE; AND SWITCH, BOX.
CAGE Information
Code | Company |
---|---|
91929 | HONEYWELL INTERNATIONAL INC. DBA HON |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 1.346 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.346 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
AAQL | BODY STYLE | BUSHING MOUNT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH RQMT OF DESC PRODUCTION STD NO. L00165 |
AXGY | MOUNTING METHOD | THREADED BUSHING |
ADAT | BODY WIDTH | 1.025 INCHES MAXIMUM |
THSD | THREAD SERIES DESIGNATOR | UNS |
AFUS | ACTUATOR HEIGHT | 0.660 INCHES MINIMUM AND 0.720 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB W/SCREW |
AFUR | ACTUATOR DIAMETER | 0.240 INCHES NOMINAL |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 220.0 AC AND 250.0 DC |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WEATHERPROOF |
AFUQ | ACTUATOR STYLE | ROUND |
CBBL | FEATURES PROVIDED | ACTUATOR SEAL |
ABXD | BUSHING LENGTH | 0.450 INCHES MINIMUM AND 0.490 INCHES MAXIMUM |
AFUX | ACTUATOR POSITION-ACTION RELATIONSHIP | UP POSITION MAINTAINED AND DOWN POSITION MAINTAINED |
CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.000 MILLIAMPERES RESISTIVE DC AND 9.000 AMPERES RESISTIVE AC |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CMLP | THREAD QUANTITY PER INCH | 32 |