Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
20950 ESPEY MFG & ELECTRONICS CORP.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
ADAQ BODY LENGTH 2.000 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 122.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 313.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP
ADAU BODY HEIGHT 1.670 INCHES NOMINAL
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
ACZB FREQUENCY RATING 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
ADAT BODY WIDTH 1.410 INCHES NOMINAL
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.910 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP