Part Number
Part Number:
NSN:
NIIN:
Item Name:
PROTECTOR , SERIES CIRCUIT
Definition:
AN ITEM SPECIFICALLY DESIGNED TO BE USED IN SERIES TRANSFORMER CIRCUITS FOR PREVENTION OF OPEN CIRCUIT RUN-AWAY VOLTAGES.
CAGE Information
Code | Company |
---|---|
59138 | INSTRUMENT TRANSFORMERS INC |
Federal Supply Class
Title
FUSES, ARRESTORS, ABSORBERS, AND
Inclusions:
INCLUDES FUSEHOLDERS; FUSE BOXES; FUSE POSTS; FUSE LINKS; FUSE BLOCKS; CURRENT LIMITERS; CORONA BALLS; ELECTROSTATIC DISCHARGERS.
Exclusions:
EXCLUDES CIRCUIT BREAKERS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | OPEN CIRCUIT PROTECTOR |
FTLD | FUNCTIONAL DESCRIPTION | USED FOR OPEN CIRCUIT PROTECTION FOR RELAY CLASSES C100 THRU C200 |
ABHP | OVERALL LENGTH | 5.000 INCHES NOMINAL |
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | JONE ELEMENT, RELAY CLASS PROTECTION C100 THRU C200; FREQUENCY 50 TO 400 HZ; AMBIENT TEMP RANCE -30 DEG C TO +55 DEG C; NORMAL SECONDARY CURRENT 5 AMPS AC; SHORT TIME OVERCURRENT 100 AMPS FOR 2 SECONDS; MAX CONTINUOUS CURRENT 10 AMPS THROUGH ONE ELEMENT OR 7.5 AMPS THROUGH ALL THREE INDEPENDENT ELEMENT; COPPER TERMINALS WITH BRASS SLOTTED PAN HEAD SCREWS NO. 8-32 X 1/4 WITH CUPPED WASHERS; WEIGHT 1.2 LBS; STANDARD BURDEN 2 OHMS; CLAMPING PEAK VOLTAGE LIMIT 400 V |
ABKW | OVERALL HEIGHT | 2.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.700 INCHES NOMINAL |