Part Number
Part Number:
NSN:
NIIN:
Item Name:
MULTIMETER
Definition:
AN INSTRUMENT WHICH IS ARRANGED TO MEASURE TWO OR MORE DIFFERENT ELECTRICAL QUANTITIES (SUCH AS VOLTS, AMPS, AND OHMS) BY MEANS OF ASSOCIATED CIRCUITS AND SWITCHES. THE VALUE IS USUALLY EXPRESSED ON A SINGLE CALIBRATED DIAL OR DIGITAL READOUT DISPLAY. FOR ITEMS WHICH ARE CONNECTED INTO A CIRCUIT AND USED CHIEFLY TO VISUALLY MONITOR AN OPERATION, SEE METER, MULTIPLE SCALE. SEE ALSO COUNTER, ELECTRONIC, DIGITAL READOUT. EXCLUDES BRIDGE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
45225 | SPX CORPORATION DIV SERVICE SOLUTION |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABMK | OVERALL WIDTH | 90.0 MILLIMETERS NOMINAL |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 MICROAMPERES, AC SINGLE INDICATOR 4TH RANGE |
STYL | STYLE DESIGNATOR | HAND-HELD |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 MICROAMPERES, DC SINGLE INDICATOR 5TH RANGE |
BHMW | MEASUREMENT RANGE | -1000.0/+1000.0 VOLTS, DC SINGLE INDICATOR 13TH RANGE |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 MILLIAMPERES, AC SINGLE INDICATOR 6TH RANGE |
BLSB | SCALE SELECTION METHOD | SWITCH |
NHCF | NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
BHMW | MEASUREMENT RANGE | -750.0/+750.0 VOLTS, AC SINGLE INDICATOR 12TH RANGE |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 MILLIAMPERES, DC SINGLE INDICATOR 7TH RANGE |
ABFY | OVERALL DEPTH | 36.0 MILLIMETERS NOMINAL |
AWZJ | POWER SOURCE | INTERNAL |
ABHP | OVERALL LENGTH | 174.0 MILLIMETERS NOMINAL |
BHSX | CIRCUIT CONSTRUCTION TYPE (NON-CORE) | ELECTRONIC, SOLID STATE |
BHMW | MEASUREMENT RANGE | -1.999/+1.999 AMPERES, AC SINGLE INDICATOR 1ST RANGE |
FEAT | SPECIAL FEATURES | ON OFF SWITCH |
BHMW | MEASUREMENT RANGE | -19.99/+19.99 MILLIOHMS SINGLE INDICATOR 8TH RANGE |
BHMW | MEASUREMENT RANGE | -1.999/+1.999 AMPERES, DC SINGLE INDICATOR 2ND RANGE |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 MILLIVOLTS, AC SINGLE INDICATOR 9TH RANGE |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 MILLIVOLTS, DC SINGLE INDICATOR 10TH RANGE |
CBBL | FEATURES PROVIDED | INTERNAL BATTERY ACCOMMODATION AND PORTABLE |
AACT | CIRCUIT CURRENT FOR WHICH DESIGNED | AC AND DC |
AMQY | INSTALLATION DESIGN | BENCH OR HAND HELD |
BFQN | DISPLAY TYPE | LIQUID CRYSTAL |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 KILOHMS SINGLE INDICATOR 3RD RANGE |
BHMW | MEASUREMENT RANGE | -199.9/+199.9 OHMS SINGLE INDICATOR 11TH RANGE |
CTWN | OPERATING VOLTAGE RATING IN VOLTS | 9.0 DC NOMINAL |
CTTD | CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 PROBE, DIRECT CONTACT AND 2 WIRE LEAD |
BFQP | DISPLAY DIGIT QUANTITY | 3-1/2 |
AMKD | INDICATOR TYPE | DIGITAL DISPLAY |