Part Number
Definition:
A TEST INSTRUMENT WHICH IS DESIGNED TO GIVE VISUAL INDICATIONS ON A CATHODE RAY TUBE OF INSTANTANEOUS VALUES AND VARIATIONS IN ELECTRICAL VOLTAGE. IT CAN ALSO BE USED TO INDICATE ANY QUANTITY WHICH CAN BE CONVERTED INTO TERMS OF ELECTRICAL POTENTIAL. IT MAY INCLUDE AN INTEGRAL PULSE GENERATOR, THE OUTPUT OF WHICH CAN BE USED TO TRIGGER AN EXTERNAL COMPONENT; BE TRIGGERED BY PULSES FROM AN EXTERNAL SOURCE, OR IT MAY UTILIZE A SPECIAL TYPE OF MULTIGUN CATHODE RAY TUBE AND CIRCUITRY WHICH PERMITS A TRACE(S) TO BE SUSTAINED AND DISPLAYED INDEFINITELY, AND THE TRACE(S) MAY BE ERASED WHEN DESIRED. FOR ITEMS WHICH ARE NOT SEPARABLE AND OPERABLE WHEN DETACHED FROM EQUIPMENT OF WHICH THEY ARE A PART (BUILT INTO OPERATIONAL EQUIPMENT), SEE INDICATOR (2) (AS MODIFIED); MONITOR (AS MODIFIED); AND RECORDER (AS MODIFIED). SEE ALSO OSCILLOGRAPH.
CAGE Information
Code | Company |
---|---|
H0G30 | KONINKLYKE LANDMACHTDM PRODUCTGROEP |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FTLD | FUNCTIONAL DESCRIPTION | A 100 MHZ COUNTER/TIMER/DMM IS INTEGRATED INTO THE SCOPE'S VERTICAL, HORIZONTAL AND TRIGGER SYSTEMS; THIS FEATURE SIMPLIFIES SETUPS BY ALLOWING CONSOLIDATED SET-UPS AND COMBINATIONS OF MEASUREMENTS; HEIGHTENS MEASUREMENT CONFIDENCE AND EXPANDS THE SCOPES VERSATILITY |
BGQQ | SINGLE TRIGGER SWEEP DURATION | 50.0 NANOSECONDS MINIMUM AND 5.0 SECONDS MAXIMUM |
FEAT | SPECIAL FEATURES | BDC TO 100 MHZ BANDWIDTH; INTEGRATED COUNTER/TIMER; 2MV SENSITIVITY; ADVANCED TRIGGER SYSTEM; 5 NS/DIV SWEEP RATE; DELAYED SWEEP MEASUREMENTS; 10X PROBE; 9 DIGIT,7 SEGMENT VACUUM-FLUORESENT PANEL |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | 100 MHZ RUGGEDIZED OSCILLOSCOPE |
FCLS | FUNCTIONAL CLASSIFICATION | AA-9.3 |
ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM |
BGQP | SWEEP FREQUENCY RANGE | +0.0/+100.0 MEGAHERTZ |
BGQM | GENERATOR DRIVEN FEATURE | NOT INCLUDED |
AMSE | VOLTAGE RATING | 100.0 VOLTS MINIMUM AND 132.0 VOLTS MAXIMUM |
BHDQ | X-AXIS FREQUENCY RESPONSE RATING | 0.0 MEGAHERTZ NOMINAL AND 2.0 MEGAHERTZ MINIMUM |
BGQN | SWEEP CIRCUIT TYPE | HORIZONTAL AND VERTICAL |
BHFH | TRACE STORAGE TUBE | INCLUDED |
BGQL | SWEEP CIRCUITS | INCLUDED |
ATES | BEAM QUANTITY | 2 |
BDJD | ACCURACY RANGE IN PERCENT | -4.0/+4.0 |
ABFY | OVERALL DEPTH | 17.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 10.800 INCHES NOMINAL |
BHDR | Y-AXIS FREQUENCY RESPONSE RATING | 0.0 MEGAHERTZ NOMINAL AND 100.0 MEGAHERTZ MINIMUM |
ABKW | OVERALL HEIGHT | 8.300 INCHES NOMINAL |
BHDZ | AMPLITUDE CALIBRATING VOLTAGE WAVEFORM | SQUARE WAVE |
ACDC | CURRENT TYPE | AC |