Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
19557 EDWARDS SIGNALING AND SECURITY SYSTE

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
TTQY TERMINAL TYPE AND QUANTITY 5 PIN ALL FUNCTIONS
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 30.0 MILLIAMPERES AC SINGLE WINDING
ABHP OVERALL LENGTH 2.500 INCHES NOMINAL
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
APCN COIL QUANTITY 1
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
APNA WINDING DC RESISTANCE RATING 20.0 OHMS NOMINAL SINGLE WINDING
ABKW OVERALL HEIGHT 1.680 INCHES NOMINAL
ABMK OVERALL WIDTH 4.000 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.157 INCHES NOMINAL SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC RESISTIVE LOAD
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY

Similar Parts

P-023079 , P023079 , 5945-00-586-4978 , 5945005864978 , 005864978