INSULATION SLEEVING , ELECTRICAL

Definition:

A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.

CAGE Information

Code Company
56352 MANHATTAN/CDT COLE-FLEX

Federal Supply Class

Title

ELECTRICAL INSULATORS AND INSULA

Inclusions:

INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
MATL MATERIAL PLASTIC, POLYVINYL CHLORIDE, MIL-I-631, TYPE F, FORM U, GRADE C, CLASS 1, CATEGORY 1
ZZZW DEPARTURE FROM CITED DOCUMENT AS MOD BY COLOR
FLEX FLEXIBILITY FLEXIBLE
ABJH TEMP RATING -10.0 DEG CELSIUS AND 105.0 DEG CELSIUS
AAGT WALL THICKNESS 0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM
ADZC ENVIRONMENTAL PROTECTION FLAME RESISTANT AND OIL RESISTANT AND MILDEW RESISTANT AND HEAT RESISTANT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
UKBG DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS 800.0 VOLTS PER MIL /0.001 INCH/
AARX INSIDE DIAMETER 0.258 INCHES MINIMUM AND 0.278 INCHES MAXIMUM
ZZZT NONDEFINITIVE SPEC/STD DATA 1 CATEGORY AND I CLASS AND U FORM AND C GRADE AND UA SUBFORM AND 2 AWG SIZE AND F TYPE
HUES COLOR CLEAR
STYL STYLE DESIGNATOR NONSHRINKABLE
CQBC MINIMUM TENSILE STRENGTH 1800 POUNDS PER SQUARE INCH